Innovate-motorsports DL-32 Manual de usuario Pagina 26

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 30
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 25
- 26 -
13.5.2 Measuring Frequency
The center section of the window changes to this:
You can enter any frequency between 10 Hz and 15000 Hz as full scale frequency. DL-32
measures the frequency with a resolution of 0.1 % of the full scale frequency specified. So in
LogWorks 0 Hz is always 0 Volt, and the full-scale frequency is equivalent to 5 Volt.
This functionality is also available for Inputs 4 and 5.
13.5.3 Measuring Speed
Select the Speed sensing function in the topmost drop-down list. The center section of the
window changes to:
With the radio buttons you can select to use metric (km/h) or US (mph) units. In the left drop-
down list you select the max speed to be measured. The DL-32 measures the speed with a
resolution of 0.1 % of the selected max speed.
In the right edit box you enter the pulses per mile the speed sensor produces. Speed sensors are
typically pulse sensors mounted either on the drive-shaft or wheel. To calculate the pulses per
mile (or km/h) click on the calculate button: